Description | Part # | Saved | Price | Select Option | Add to |
---|---|---|---|---|---|
ETher Victor 2.2D Eddy Current Flaw Detector for Automated Inspections | EC-ET-KICOM001 |
|
Request Pricing |
The ViCTor 2.2D is a user friendly automated eddy current inspection system designed with the Automation Engineer in mind. Based on the AeroCheck+, NDT Inspectors will become quickly familiar with its user interface and with a variety of case configurations available. The ViCTor 2.2D offers maximum flexibility for each individual application.
Ideally suited to inspection automation for the following reasons:
Probe | Connectors | 2 off 12 Way Lemo 2B (Absolute, Bridge and Reflection) and Lemo 00 (for single element absolute probes) |
Rotary | Probe 1 only. 600-3000 rpm - ETher Mercury Drive (ARD002), Hocking 33A100 / 40A100, Rohmann MR3 and SR2 Drive (special adapter needed). | |
Connectivity | Probe 1 only. Option becomes active with use of AeroCheck+ conductivity probe and cable | |
Frequency | Dual Frequency | 10 Hz to 12.8 MHz |
Gain | Overall | -18 to 104 dB |
Main Gain | -18 to 82dB, 0.1, 1 and 6dB steps | |
Input | 0dB or 12dB | |
Drive | 0dB, 6dB and 10dB (0dB reference 1mW into 50 ohm) | |
Max X/Y Ratio | -18dB to 82dB independent | |
Phase | Range | 0.0 - 359.9°, 0.1° steps |
Filters | Normal High Pass | DC to 2kHz or Low Pass Filter, which ever is the lower in 1 Hz steps. Plus variable adaptive balance drift compensation 0.01 - 0.5 Hz (6 steps). |
Normal Low Pass | 1Hz to 2kHz or a quarter of the lowest test frequency whichever is lower in 1Hz steps. | |
Balance | Manual | 14 internal balance loads; 2.2µh, 5.0µh, 6.0µh, 6.5µh, 7.0µh, 7.5µh, 8.2µh, 12µh, 15µh, 18µh, 22µh, 30µh, 47µh, 82µh |
Automatic | Optimized balance load selection | |
Mix Channel | Frequency | Full frequency range available on both channels |
Probe Mode | Simultaneous reflection / bridge and absolute including simultaneous two probe Differential and Absolute | |
Mix Gain | X/Y -18 to 18dB | |
Mix Phase | 0.0 - 359.9°, 0.1° steps | |
Alarm Gates | Number | 2 independent Alarm Gates may be configured on Pane 1, Pane 2 or Both Panes (logical or) |
Box | Fully configurable, Freeze, Tone or Visual | |
Sector | Fully configurable, Freeze, Tone or Visual | |
Display | Type | 5.7" (145mm), 18 bit color, daylight readable |
Viewable Area | 4.5" (115.2mm) Horizontal x 3.4" (86.4mm) Vertical | |
Resolution | 640 x 480 pixels | |
Color Schemes | User configurable Dark, Bright and Black & White | |
Configurable Screen | Full Screen, Single, Dual Spot or Dual Pane with variable size and location and functions. e.g. XY, Time base, Waterfall and Meter. | |
Display Modes | Spot, Time base (0.1-20 seconds x 1-200 sweeps and up to 55 seconds), Waterfall and Meter with peak hold and % readout. | |
Graticules | None, Grid (4 sizes: 5, 10, 15 and 20% FSH), Polar (4 sizes: 5, 10, 15 and 20% FSH) | |
Offset | Spot Position: Y=-50 to 50, X=-65 to 65% | |
Spot Readout | Display X, Y, or R, θ | |
Summary | Display of all settings in Legacy Format | |
Removable Data Storage | Setup Storage | micro SD up to 32GB, holding over 10,000 settings |
Stored Screen Shots | micro SD up to 32GB, holding over 10,000 screen shots | |
Recorded Data | micro SD up to 32GB, holding over 500 2.5 minute long data recordings | |
Guides | micro SD up to 32GB, holding 10,000 slides | |
Advanced Features | Data Logging | Real-time recording of signal data and replay on instruments and desktop PC up to 164 seconds |
Guides | Create and display a slide show containing instructions, tutorials and procedures using Microsoft PowerPoint | |
Attachments | Screenshots and Data Recordings are saved in a folder with the name of the Settings | |
Loop | Capture a live repetitive signal and then optimize the instrument settings (Phase, Gain, Filters) to simplify optimizing the parameters. | |
Trace | Allows a calibration reference signal to be stored on the screen and then compared with the live signal | |
Auto Phase | Allows phase angle to be automatically set to a pre set angle | |
Inputs/Outputs | PC Connectivity | USB (Full PC remote control plus Real Time data) and RS232 May be set off, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600 baud |
Analogue | 2 outputs 2 Volts swing | |
Digital Volt Free Alarm | on Lemo 12 way Open collector transistor (36 V DC at 10mA Max.) | |
VGA | Full 15 way VGA output (EC screens only) | |
l/O | Two configurable | |
Alarm Out | 2 off Opto isolated 2mA 50V Max. | |
External Alarm Inhibit | 2 TTL inputs | |
Languages | English, French, Spanish, Italian, Portuguese, Russian, Japanese, Chinese, Turkish, Czech | |
Verification | The system includes on delivery a 2 yr. validity Verification Level 2 detailed functional check and calibration as per ISO 15548-1:2013 | |
Power on Self Test | The system performs a self test on start up of external RAM, SD, RAM, accelerometer, Micro SD card, LCD screen buffer | |
Power | External | 100-240VAC, 50-60Hz, 30 Watts |
Physical | Weight | 7.25 lbs. (3.3 kg) |
Size (WxHxD) | 9.7" x 6.0" x 9.9" (246 x 152 x 250 mm) | |
Operating Temperature | -4° to 140° (-20° to 60°C) | |
Storage Temperature | Storage for up to 12 months -4° to 95°F (-20° to 35°C) Nominal 68°F (20°C) | |
IP Rating | IP54 (front panel only) |
KAWEL001 Weld Probe + Accessories Kit Includes
KAWEL002 Advanced Weld Probe + Accessories Kit Includes
KASUR001 Surface Inspection Kit Includes
KASUBS001 Sub Surface, Low Frequency Inspection Kit includes
KAROT001 Rotary Drive Inspection Kit Includes
KACON001 Conductivity, Standard 13mm Probe Inspection Kit Includes (NIST ONLY)
KATUB001 Tube Inspection Kit Includes
Description | Part # | Saved | Price | Select Option | Add to |
---|---|---|---|---|---|
ETher Victor 2.2D Eddy Current Flaw Detector for Automated Inspections | EC-ET-KICOM001 |
|
Request Pricing |