Karl Deutsch Echograph 1095 Flaw Detector

Karl Deutsch Echograph 1095 Flaw Detector

Precise Measurement and Easy Operation with Clear Text

A New Generation of Manual Ultrasonic Testing

High-tech meets comfort

Besides the proven qualities of its predecessor model, the new Echograph 1095 Ultrasonic Flaw Detector features time corrected gain and backwall echo attenuation. Designed as an ideal instrument for manual ultrasonic testing, it is equipped with sturdy mechanical and electronic components with a large, high-contrast screen and a convenient, practical user interface, making it nearly indestructible even in harsh operating environments or outdoors.

Powerful, compact and user-friendly

This powerful ultrasonic flaw detector features 3 monitors for amplitude and time-of-flight measurement and 3 associated status lamps on the front panel for monitoring of threshold levels. It is very compact at 2.2" case depth(54 mm) and provides fast digital ultrasonic electronics with a high sampling rate and pulse repetition frequencies up to 5000 Hz.

 

Operating assistance for less-experienced users

Convenient user guidance supports less-trained UT inspectors, also during probe handling and instrument adjustment. Simply activate the wizard and follow the instructions on the screen. Even difficult evaluation procedures for defect sizing (DAC/TCG, JIS, AWS or DGS) are set almost automatically.

 

 

 

 

Features:

  • Displays up to 6 measured values in large digits
  • Equipped with 3 monitors to measure amplitude and time-of-flight, as well as 3 associated control lamps on the front panel to monitor exceeding or dropping below threshold values
  • Enables reference echoes and to record echo dynamics
  • Allows movement of all 3 monitor gates in "freeze" mode and recalculation of the displayed measured values.
  • Contains a probe data base for easy entering of probe data, even for third-party probes
  • Saves all data, e.g. screenshots as BMP files or series of measurement as CSV files for a simple data export on a removable 8 GB SD flash card
  • Distance evaluation even on curved surfaces (e.g. pipes)
  • Adjustable square pulsar with a pulse width automatically adapted to the frequency of the probe when it is loaded, and can be changed manually if needed
  • Digital filters for optimal adaption to the probe
  • Dust-proof and provides protection against water jets according to IP65
  • Rugged metal housing with anti-reflection protection glass screen and rubber protective holster for rough environment conditions
  • Operate independent of AC power supply by means of the built-in lithium-ion battery (charging of the battery is possible during testing if connected to AC power)
  • Update and upgrade options via the SD-card
  • All features according to EN 12668-1

Available Models

Echograph 1095 Basic

#1095.020

Echograph 1095 DAC/TCG/AWS

#1095.030

Echograph 1095 DGS/DAC/TCG

#1095.040

Echograph 1095 DGS/DAC/TCG/
AWS/JIS

#1095.050

Matrix Memory, TOFD and B-Scan Available Upon Request

 

Evaluation Methods

DGS Method Option:

  • Not restricted to special probes (DGS curve is calculated within the instrument)
  • Visualization of the reference DGS curve
  • Defect size (FBH = flat bottom hole) is directly shown
  • DGS with KARL DEUTSCH TR probes
  • Indication of up to 6 additional threshold curves

DAC Method Option

  • Reference line method (EN 1330-4)
  • Optical and acoustical alarm when exceeding or dropping below the curve
  • Indication of up to 6 threshold curves
  • DAC support points can be manually added, shifted and deleted (up to 16 points)
  • Calculation of time corrected gain from the DAC curve

 

Time Corrected Gain (TCG) Method

For TCG evaluation the gain is adjusted depth-dependent according to the previously recorded DAC curve (option). As a result, reflectors with equal sizes are displayed with equal amplitudes even though they are located in different depths.

Backwall Echo Attenuation Method

Often flaw echoes between transmitter pulse and backwall echo are much smaller than a backwall echo used for monitoring of coupling. With backwall echo activated attenuation monitor 3 can be shifted over the backwall echo and a separate gain can be selected. As a result, it is possible to show all interesting echoes in a useful height (in the example picture: amplification 28 dB within and 45 dB outside of monitor 3).

High-Precision Wall Thickness Measurement Mode

High-precision distance measurement is executed with the aid of signal zero crossing and uses the RF-mode. Exclusively considering zero crossings minimizes influences of amplification and signal shape, thus wall thickness values are highly accurate and stable. Besides arithmetic averaging, storing of minimal and maximal values is available. As a result, the unit is optimized e.g. for the measurement of corrosion.

 

Kit Includes:

  • Instrument with red protective holster
  • Li-ion battery
  • AC charger
  • Transport case
  • eCom 95 PC software for Windows XP(SP3+)/7/8/8.1/10

 

Optional Accessories:

  • Carrying case including carrying belt
  • Replacement carrying strap
  • USB cable
  • Spare battery 7.4V; 7.6 Ah
  • Charger unit for external charging of a spare battery

Product Literature

Description Part # Saved Price Select Option Add to
Karl Deutsch Echograph 1095 Flaw Detector - Basic UT-KD-1095.020 Request Pricing
Karl Deutsch Echograph 1095 Flaw Detector - DAC/TCG/AWS UT-KD-1095.030 Request Pricing
Karl Deutsch Echograph 1095 Flaw Detector - DGS/DAC/TCG UT-KD-1095.040 Request Pricing
Karl Deutsch Echograph 1095 Flaw Detector - DGS/DAC/TCG/AWS/JIS UT-KD-1095.050 Request Pricing
Module "Matric & B-, L-scan & TOFD - for Karl Deutsch Echograph 1095 UT-KD-1910.502 Request Pricing
Combined Case & Accessories (Carrying Case) - for Karl Deutsch Echograph 1095 UT-KD-6189.101 Request Pricing
Instrument Case with Carrying Strap - for Karl Deutsch Echograph 1095 UT-KD-6189-301 Request Pricing
Combined Case and Accessories (magnet + strap) - for Karl Deutsch Echograph 1095 UT-KD-618.201 Request Pricing