Individual Penetrameters / IQI's - ASTM-E-1742

Individual Penetrameters / IQI's - ASTM-E-1742

Overview

Individual ASTM-E-1742 Penetrameters come in a full range of thicknesses, sizes and materials. Lead figures identify the thickness of the material to be radiographed on one end and the material of the IQI on the other end. Serialization and Calibration are available, as well as Encapsulation in clear, thin plastic and Wood Cases. Wood cases come in two sizes for encapsulated and non-encapsulated IQIs, and are engineered to prevent loss and damage by keeping IQI's firmly in place using a shock absorbing sponge rubber insert in the lid.

Penetrameter Sets are also available:

ASTM-E-1742 Penetrameter Sets

 

 

Mounting Blocks & Step Wedges

Mounting blocks are used when it is impractical to place the IQI directly on the object being radiographed. Standard mounting blocks are supplied in sizes corresponding with ASTM E-1742 IQI sizes. Their dimensions allow at least 1/8" clearance on three sides of the IQI.

Step wedges that are used for calibration and evaluation of techniques are also available. When an object with varying thicknesses is radiographed a step wedge of the same material, incorporating the same thickness, may often be advantageously used.

Click Here for Shims, Mounting Blocks & Step Wedges

Technical Specifications

General Dimensions & Thickness

General Dimensions

 Size Length Width  Image
 2.5" and smaller  2"  1/2"
 2.6" to 8"  2.850"  1"
8" to 19.5"
(available in .5" increments)
Diameter equal to 4 x Thickness Diameter equal to 4 x Thickness
(# of holes: 2)
20" +
(available in whole increments)
Diameter equal to 4 x Thickness Diameter equal to 4 x Thickness
(# of holes: 2)

 

Thickness

2% of the thickness of the material to be radiographed, to the nearest fractional size. Minimum thickness: 0.005"

Thickness Guide for Plaque Type IQI's

Hole Sizes

Small Hole Diameter 1 x Thickness (min: 0.010")
Medium Hole Diameter 2 x Thickness (min: 0.020")
Large Hole Diameter 4 x Thickness (min: 0.040")
Materials & Sizes

Sizes

Available in a range from .01" to 20.0"

Note: Per ASTM-E-1742, IQI's under .25" will be marked with the requested size, but will have the same thickness and hole sizes as a .25" IQI. If true 2% thickness IQI's are required for sizes under .25”, see True 2% Penetrameters / IQI's - ASTM-E-1742

Available Materials

  • Aluminum (6061)
  • Steel (1018)
  • Stainless Steel (304)
  • Aluminum 2014, 2024, 2219, 7075
  • Aluminum-Bronze
  • Brass
  • Copper
  • Cupro-Nickel
  • Inconel 600
  • Magnesium AZ 31 & ZK60
  • Monel 400
  • Nickel
  • Phosphor-Bronze
  • Cobalt (Haynes 25, Haynes 188)
  • Hastelloy (C or X)
  • Inconel 625 & 718
  • Plastics / Nylon
  • Rene 41
  • Titanium
  • Waspaloy
  • Zirconium

Purchasing Instructions

Individual IQI pricing is based on material and size. You must identify the Group Number for Material and Group Letter for Size Range based on the actual material and size you require.

Step 1
Select Material Group that contains required IQI material
Group Number Material
1 Aluminum (6061)
Steel (1018)
Stainless Steel (304)
2 Aluminum 2014, 2024, 2219, 7075
Aluminum-Bronze
Brass
Copper
Cupro-Nickel
Inconel 600
Magnesium AZ 31 & ZK60
Monel 400
Nickel
Phosphor-Bronze
3 Cobalt (Haynes 25, Haynes 188)
Hastelloy (C or X)
Inconel 625 & 718
Plastics / Nylon
Rene 41
Titanium
Waspaloy
Zirconium
Step 2
Select Size Group that contains required IQI size
  • The size specified should represent the thickness of the material to be radiographed.
  • The actual thickness of the IQI will be 2% of the size specified.
  • Per ASTM-E-1742, IQI's under .25" will be marked with the requested size but will have the same thickness and hole sizes as a .25" IQI. If true 2% thickness IQI's are required for sizes under .25”, see True 2% Penetrameters / IQI's - ASTM-E-1742.

If you are unsure what size you require, see the following guide:

Thickness Guide for Plaque Type IQI's

Sizes for Material Groups 1 & 2
Group A / Size Range: 0.25" - 1.0"
Available Sizes: 25", .31", .37", .43", .50", .56", .62", .68", .75", .81", .87", .93", 1.0"
Group B / Size Range: 1.1" - 2.5"
Available Sizes: 1.1", 1.2", 1.3", 1.5", 1.6", 1.7", 1.8", 2.0", 2.1", 2.2", 2.3", 2.5"
Group C / Size Range: 2.6" - 5.0"
Available Sizes: 2.7”, 3.0”, 3.2”, 3.5”, 3.7”, 4.0”, 4.5”, 5.0”
Group D / Size Range: 5.2" - 8.0"
Available Sizes: 6.0”, 7.0”, 8.0”
Group E / Size Range: 8.5" - 20.0"
Available Sizes: 8.5", 9.0", 9.5", 10.0", 10.5", 11.0", 11.5", 12.0", 12.5", 13.0", 13.5", 14.0", 14.5", 15.0", 15.5", 16.0", 16.5", 17.0", 17.5", 18.0, 18.5", 19.0, 19.5", 20.0"
Sizes for Material Group 3
Group A / Size Range: 0.25" - 2.5"
Available Sizes: .25", .31", .37", .43", .50", .56", .62", .68", .75", .81", .87", .93", 1.0", 1.1", 1.2", 1.3", 1.5", 1.6", 1.7", 1.8", 2.0", 2.1", 2.2", 2.3", 2.5"
Group B / Size Range: 2.7" - 8.0"
Available Sizes: 2.7”, 3.0”, 3.2”, 3.5”, 3.7”, 4.0”, 4.5”, 5.0”, 6.0”, 7.0”, 8.0"
Group C / Size Range: 8.0" - 20.0"
Available Sizes: 8.5", 9.0", 9.5", 10.0", 10.5", 11.0", 11.5", 12.0", 12.5", 13.0", 13.5", 14.0", 14.5", 15.0", 15.5", 16.0", 16.5", 17.0", 17.5", 18.0, 18.5", 19.0, 19.5", 20.0
Step 3
Optional IQI Serialization, Calibration, and Encapsulation

IQI’s may be purchased with or without serialization, calibration, and encapsulation. Add these additional options to your order if required. Quantity should match number of IQI’s the option applies to.

Serialization Only: PN: RT-RC-P-Serialize

Serialization & Calibration: PN: RT-RC-P-Serialize-Cal

Encapsulation: PN: RT-RC-P-Encapsulate

 Step 4
Add Items to Cart
Select your desired material from the top dropdown item, and your item range in the Pricing Section. Input the number of desired IQIs to the right of the dropdown menu. If the IQIs are to be serialized and/ or calibrated, the number of desired IQIs should match the serialization / calibration option. (I.e., if ordering 3 IQIs that need serialization, input '3' in the 'Individual IQI, Serialize' quantity field)
 Step 5
Checking Out
During checkout, list Individual sizes in the 'Other Comments' field under 'Shipping

*Specify individual sizes in the comments section during checkout.

Minimum Order Size is $75

Note: Serialized radiographic products are not returnable

Description Part # Saved Price Select Option Add to
Individual IQI ASTM-E-1742, Plaque Type, Material Group 1 (select material and size range)
Model #
RT-RC-P-ASTM-E-1742-1 - Master $14.00
Individual IQI ASTM-E-1742, Plaque Type, Material Group 2 (select material and size range)
Model #
RT-RC-P-ASTM-E-1742-2 - Master $18.00
Individual IQI ASTM-E-1742, Plaque Type, Material Group 3 (select material and size range)
Model #
RT-RC-P-ASTM-E-1742-3 - Master $60.00
Individual IQI, Serialize RT-RC-P-SERIALIZE $1.00
Individual IQI, Serialize and Calibrate RT-RC-P-SERIALIZE-CAL $9.00
Individual IQI, Encapsulate RT-RC-P-ENCAPSULATE $4.00
IQI Case RT-RC-P-CASE $113.00