| Description | Part # | Saved | Price | Select Option | Add to |
|---|---|---|---|---|---|
| Dakota CMX10-DL Thickness Gauge | UT-DU-CMX10-DL |
|
Request Pricing | ||
The Dakota CMX10-DL Thickness Gauge is a “universal” ultrasonic thickness gauge that can be used for virtually any common thickness gauging application. Precision measurements of thin materials with delay line probes, Corrosion and general measurements with Dual probes. Includes both A- and B- scan displays. Enhanced TCG & BEA for highly attenuative materials. Through-Coating with coating thickness is standard a NEW 2nd layer feature allows users to assess and predict remaining inner liner thickness.



The Dakota CMX10-DL Thickness Gauge is capable of precision and corrosion inspections. Applications include:

The CMX10-DL can be used with most transducers:
The CMX-10DL can also be used for basic flaw detection applications with straight beam and angle beam transducers.
For more information, see Dakota Probes for Precision Thickness Gauges and Dakota NDT Probes By Test Modes.
| Dakota CMX10-DL — A-Scan Thickness Gauge Specifications | |
| Ultrasonic Specifications | |
| Screen Displayed Range: | 23.3" (592 mm) |
| Measurement Modes / Range: | Pulse-Echo (P-E): 0.007" – 58.3" (0.18 mm – 1480 mm) Thru-Paint Echo-Echo (E-E): 0.007" – 23.3" (0.18 mm – 592 mm) Thru-Paint Verify (E-EV): 0.007" – 11.7" (0.18 mm – 296 mm) 2nd Layer Thickness (PE2): 0.007" – 58.3" (0.18 mm – 1480 mm) 2nd Layer Thru-Paint (EE2): 0.007" – 23.3" (0.18 mm – 592 mm) |
| Velocity Range: | 0.0079 – 0.7874 in/μs (200 – 20,000 m/sec) |
| Transmitter Pulse: | Square |
| Transmitter Pulse Voltage (peak-to-peak): | 50 – 200V (User Adjustable in 1V steps) |
| Pulse Rise Time: | <10 ns |
| Pulse Duration: | 25 – 250 nS (Dependent on probe frequency) |
| Gain Control: | 0 – 74 dB in 0.1 dB steps; Time Controlled Gain, Auto80 |
| Frequency Range: | 1 MHz – 20 MHz |
| Transducer | |
| Transducer Types: | Dual Contact, Single Contact, Single Delay, Angle Beam |
| Auto Detect: | Auto Detect and Transducer Set Up Features |
| Product Features | |
| Resolution: | ±0.0001" (±0.001 mm) |
| Accuracy: | 0.001" (±0.01 mm) or ±1% of Reading (whichever is largest) *@ 5MHz 1/4" on Steel |
| Minimum Measurement (Steel @ 19,423 ft/s): | 0.007" (0.18 mm) |
| Maximum Measurement (Steel @ 19,423 ft/s): | 23.3" (592 mm) | Delay: 0.1" – 35" (-3 mm – 888 mm) |
| Calibration Options: | Zero, 1 Point, 2 Point, Custom Velocity & Preset Material |
| Gate Modes: | Flank, Zero-Cross, Peak |
| Number of Gates: | 1 – 3 Depending on Mode Selected |
| Filter Settings: | Low Pass (10 MHz, 20 MHz, 30 MHz) | High Pass (0.5 MHz, 2.5 MHz, 5 MHz) | Broadband |
| Signal Averaging: | 1 – 32 Samples (Adjustable) |
| Time Corrected Gain (TCG): | Ramp, Curve (up to 16 points) |
| Pulse Repetition Frequency (PRF): | 2 KHz |
| Back Wall Echo Suppression (BEA): | Yes |
| V-Path Correction: | Automatically corrects for V-path (DakotaNDT transducers only) |
| DakMaster™ Software: | PC Software for Reports, Configurations and Back Ups |
| DakMaster™ Mobile App: | Record and Report Instantly via Mobile Device |
| Memory | |
| Data Output: | USB and Bluetooth LE |
| Internal Storage: | 128 MB Internal; up to 32 GB with External Memory Card |
| Log Formats: | Sequential, Grid, Recording, Amplitude/Depth Color Option |
| Screen Capture: | On Gauge and Screen View function in DakMaster™ |
| Full Traceability: | Feature Set Up Library, Transducer Library, Calibration Library |
| Data Log File Formats: | Projects, Folders, Individual Files |
| Display | |
| Display: | 800 x 480 px, Colour, Touchscreen, Graphical, TFT |
| Display Refresh Rate: | 60 Hz (16 ms) |
| Waveform Refresh Rate: | 20 Hz (50 ms) |
| Display & Recall: | Numerical Reading, A-Scan, B-Scan and Video Recordings stored and retrieved in Data Logs |
| A-Scan: | Rectified +/-, RF, Full Wave |
| B-Scan Timed: | Recording and Analysis with 2 Cursor Measurement |
| Differential Mode: | Automatically calculates difference from nominal |
| Display Freeze: | Freeze Screen and Overlay Signal on Screen |
| Brightness Adjust: | Manual and Automatic |
| Selectable Display Configurations: | A-Scan, Statistics, Live Reading, Grid, Image Collect |
| Screen Share & Control: | Remote Viewing Feature with Control |
| Gauge Specification | |
| Part Number: | CMX10-DL |
| Controls: | Keypad Only, Touchscreen Only, or Keypad & Touchscreen Combined |
| Dimensions: | 7.1" x 4.1" x 2.0" (180 x 105 x 50 mm) |
| Weight: | 1.92 lbs (872 g) |
| Operating Temperature: | 14°F – 122°F (-10°C – 50°C) |
| Probe Sockets: | 1/2x Lemo-00 | 1x ODU Smart Port |
| Power Supply: | LI-Ion Rechargeable Smart Battery or Mains Power Supply |
| Battery Life: | 9 – 15 hrs (Dependent on usage) |
| Ingress Protection: | IP65 — Dust tight, protected against low power water jets in any direction |
| Certification: | Designed for EN 15317 |
| Warranty: | 1 Year Limited |
| Manufacture: | Made in the United Kingdom |
| Packing List: | CMX10-DL Gauge, Ultrasonic Couplant 4 fl oz (120 ml), Power Supply (UK/EU/US Adapters), Rechargeable Battery, Hand Strap (x1), Extension Straps (x2), Screen Protector (x1), USB Cable, Calibration Certificate, User Guide, DakMaster™ Download Card, Transit Case |
|
|
|
|
| Description | Part # | Saved | Price | Select Option | Add to |
|---|---|---|---|---|---|
| Dakota CMX10-DL Thickness Gauge | UT-DU-CMX10-DL |
|
Request Pricing | ||