Penetrameters / IQI Sets - ASTM-E-1025

Penetrameters / IQI Sets - ASTM-E-1025

Overview

ASTM-E-1025 Penetrameters are available in two sets: Standard Set A of 25 sizes with choice of material and Standard Set B of 11 sizes with choice of material. All sets include a wood case designed to prevent loss and damage by keeping IQI's firmly in place using a shock absorbing sponge rubber insert in the lid. A notch system is used on the IQI to identify 8 grades of materials in order of increased attenuation, and lead figures identify the thickness of the material to be radiographed on the other end. In addition, the material and specification are etched into the IQI. Serialization and Calibration are available, as well as Encapsulation in clear, thin plastic.

For Individual Penetrameters and Shims, Mounting Blocks & Step Wedges, see below links.

Individual Penetrameters Shims, Mounting Blocks & Step Wedges

 

Standard Sets

Please specify material in comments section during checkout. Refer to Purchasing Instructions for ordering details.

Set A

Set A consists of twenty-five IQI’s in a case and contains the following sizes:

  • 5, 6, 7, 9, 10, 11, 12, 13, 15, 16, 17, 18, 20, 22, 25, 27, 30, 32, 35, 37, 40, 42, 45, 47, 50

Set B

Set B consists of eleven IQI’s in a case and contains the following sizes:

  • 55, 60, 65, 70, 75, 80, 90, 100, 120, 140, 160

IQI Technical Specifications

General Dimensions & Thickness

General Dimensions

Size Length Width Image
#50 and smaller 11/2" 1/2"
#50 - #160 21/4" 1"
#160 - #390
(Available in .5 increments)
Diameter equals to 4 x Thickness Diameter equal to 4 x Thickness
(# of holes: 2)
#400 +
(Available in whole increments)
Diameter equals to 4 x Thickness Diameter equal to 4 x Thickness
(# of holes: 2)

 

Thickness

2% of the thickness of the material to be radiographed to the nearest fractional size.
Minimum Thickness: 0.005" or per below table

Standard Image Quality Levels
Image Quality Levels IQI Thickness Minimum Perceptible Hole Diameter Equivalent IQI Sensitivity*
2-1 T 1/50 (2%) of Specimen Thickness T 1.4%
2-2 T** T 2.0%
2-4 T T 2.8%
Special Image Quality Levels
1-1 T 1/100 (1%) of Specimen Thickness T 0.7
1-2 T T 1
4-2 T 1/25 (4%) of Specimen Thickness T 4

*Equivalent IQI sensitivity is that thickness of the IQI, expressed as a percentage of the part thickness, in which the 2 hole would be visible under the same conditions.

**For Level 2-2 Radiologic - the 2 hole in an IQI, 1/50 (2%) of the specimen thickness, is visible

 

Thickness Guide for Plaque Type IQI's

Hole Sizes

Small Hole Diameter 1 x Thickness (min: 0.010")
Medium Hole Diameter 2 x Thickness (min: 0.020")
Large Hole Diameter 4 x Thickness (min: 0.040")
Materials

 Available Materials

  • Aluminum (6061)
  • Steel (1018)
  • Stainless Steel (304)
  • Aluminum 2014, 2024, 2219, 7075
  • Aluminum-Bronze
  • Brass
  • Copper
  • Cupro-Nickel
  • Inconel 600
  • Magnesium AZ 31 & ZK60
  • Monel 400
  • Nickel
  • Phosphor-Bronze
  • Cobalt (Haynes 25, Haynes 188)
  • Hastelloy (C or X)
  • Inconel 625 & 718
  • Plastics / Nylon
  • Rene 41
  • Titanium
  • Waspaloy
  • Zirconium

Purchasing Instructions

IQI Set A and B pricing is based on material. You must identify the Group Number for the Material based on the actual material you require.

Step 1: Material

Select Material Group that contains required IQI material

Group Number Material
1 Aluminum (6061)
Steel (1018)
Stainless Steel (304)
2 Aluminum 2014, 2024, 2219, 7075
Aluminum-Bronze
Brass
Copper
Cupro-Nickel
Inconel 600
Magnesium AZ 31 & ZK60
Monel 400
Nickel
Phosphor-Bronze
3 Cobalt (Haynes 25, Haynes 188)
Hastelloy (C or X)
Inconel 625 & 718
Plastics / Nylon
Rene 41
Titanium
Waspaloy
Zirconium

Step 2: Additional Options

IQI sets may be purchased with or without serialization, calibration and encapsulation. Add these additional options to your order that matches the set being purchased if required.

Serialization Only:
Set A: RT-RC-P-SERIALIZE-SET-A
Set B: RT-RC-P-SERIALIZE-SET-B

Serialization & Calibration: 
Set A: RT-RC-P-SERIALIZE-CAL-SET-A
Set B: RT-RC-P-SERIALIZE-CAL-SET-B

Encapsulation: 
Set A: RT-RC-P-ENCAPSULATE-SET-A
Set B: RT-RC-P-ENCAPSULATE-SET-B

Note: If you choose to encapsulate your IQIs, there will be an additional cost of $52.00 for the larger case.

  

Purchasing Example

(refer to price table at bottom of page for product selection)

  1. Requirement: IQI Set A in Nickel, Serialized
    1. Locate product titled: "ASTM-E-1025 Sets, Material Group 2"
      1. Select "Set A" from the drop-down menu (PN: RT-RC-PK-ASTM-E-1025-A-2)
      2. Select Add to Cart
    2. Locate product titled: "IQI Set Serialization for Set A" (PN: RT-RC-P-SERIALIZE-SET-A)
      1. Select Add to Cart
    3. During checkout, list: "Material: Nickel" in comments field

*Specify actual Material in comments section during checkout

Note: Serialized radiographic products are not returnable

Description Part # Saved Price Select Option Add to

Sets

ASTM-E-1025 Sets, Material Group 1 (Specify set)
Model #
RT-RC-PK-ASTM-E-1025-A-1-Master $505.00
ASTM-E-1025 Sets, Material Group 2 (Specify set)
Model #
RT-RC-PK-ASTM-E-1025-A-2-Master $606.00
ASTM-E-1025 Sets, Material Group 3 (Specify set)
Model #
RT-RC-PK-ASTM-E-1025-A-3-Master $1,626.00

Additional Options

IQI Set Serialization for Set A RT-RC-P-SERIALIZE-SET-A $25.00
IQI Set Serialization and Calibration for Set A RT-RC-P-SERIALIZE-CAL-SET-A $225.00
IQI Set Encapsulation for Set A RT-RC-P-ENCAPSULATE-SET-A $100.00
IQI Set Serialization for Set B RT-RC-P-SERIALIZE-SET-B $11.00
IQI Set Serialization and Calibration for Set B RT-RC-P-SERIALIZE-CAL-SET-B $99.00
IQI Set Encapsulation for Set B RT-RC-P-ENCAPSULATE-SET-B $44.00