BAQ dynaROCK II Universal Rebound Hardness Tester

BAQ dynaROCK II Universal Rebound Hardness Tester

BAQ dynaROCK II
Universal Rebound Hardness Tester

dynarock 11

The dynaROCK II works according to the Leeb rebound hardness test method for metallic materials. It combines easy operation with high precision and reliability. For different applications, six impact device types are available. The type of the connected impact device is identified automatically.

Features:

  • Fast and easy hardness testing
  • Measuring method according to DIN 50156, DIN EN ISO 16859 and ASTM A956
  • Robust metal (aluminum) casing
  • Large color display
  • Embedded Li-ion battery
  • 12 groups of materials
  • Extensive storage and statistical functions
  • USB interface and PC software

dynaROCK ll LCD Screen
    • Hardness Scale
    • Impact device type
    • Impact direction
    • Material
    • Mean value
    • Number of measurements
    • Standard deviation
    • History

    dynaROCK ll probes Impact Devices
    Type D Standard impact device for most hardness testing tasks
    Type DC Extremely short impact device for measurements at difficult-to-access locations or in pipes
    Type C Impact device with reduced impact energy e.g. for measurements on surface-hardened parts
    Type D+15 Impact device with small placement surface
    Type DL Impact device with longer impact body
    Type G Impact device with increased impact energy for measurements on heavy castings and forged parts. The surface quality requirements are lower as with type D. Measurement range up to Brinell 650HB.


    Specifications:

    Hardness Scale HRC, HB, HV, HRB, HL, HS and tensile strength
    Display Color LCD 320 x 240 pixels
    Statistics Average value, standard deviation, minimum, maximum
    Data Memory 500,000 data records with date, time, GOOD / BAD rating and impact direction
    Interface USB
    Data Transfer Direct protocol printout with mini thermal printer
    PC-software
    data transfer on USB flash device
    Power Supply Integrated rechargeable lithium-ion battery
    Charging By charging adapters or by PC-USB
    Operating Time Approximately 16 hours
    Languages Menu: English, German, French, Italian, Spanish, Polish, Russian, Turkish.
    Manual: English, German, French, Italian, Spanish
    Dimensions 5.3" x 3.1" x 0.8" (135 x 79 x 22 mm)
    Weight 1 lb. (425 g) including impact device D and cable
    Minimum weight on the sample on stable underlay 4.4 lbs. (2 kg)


    Scope of Delivery:

    • Basic device
    • Impact device type D with cable
    • Calibrated hardness comparison block
    • Cleaning brush
    • Manual
    • Interface cable
    • Small replacement ring
    • USB charging adapter
    • PC software
    • Case


    Optional Accessories:

    • Placement rings for measurement on curved surfaces
    • Different impact devices
    • Mobile mini printer
    • Hardness comparison blocks with calibration certificate for impact devices Dxx and C in 3 different hardnesses
    • Hardness comparison blocks with calibration certificate for impact device G in 2 different hardnesses
    • Carrier bag


    *Made in Germany

    Product Literature

    Description Part # Saved Price Add to
    Carrying bag with shoulder strap for dynaROCK II with impact device HT-BAQ-21-113-EN $120.00
    Connection cable for dynaROCK II Impact Device HT-BAQ-R-RP-KABEL-EN $130.00
    Impact Body type D HT-BAQ-R-RP-SK-D-EN $135.00
    Impact Body type DL HT-BAQ-R-RP-SK-DL-EN $380.00
    Impact Body type G HT-BAQ-R-RP-SK-G-EN $380.00
    Impact Device C for Hardness Tester dynaROCK II - Impact device with lower impact energy e.g. for measurements on surface-hardened parts. The impressions are approximately only half as deep as in case of impact device D, however the requirements on t HT-BAQ-21-124-EN $935.00
    Impact Device D for hardness Tester dynaROCK II - Standard impact device for most hardness testing tasks HT-BAQ-21-120-EN $935.00
    Impact Device D+15 for Hardness Tester dynaROCK II - The impact device has a recessed reactance coil and a smaller placement surface (0.4" x 0.55" x 0.8")(11 mm x 14 mm instead of 20 mm) for hardness measuring in slots and deepened areas. HT-BAQ-21-123-EN $1,065.00
    Impact device DC for Hardness Tester dynaROCK II - Extremely short impact device for measurements in inaccessible locations or in pipes. HT-BAQ-21-122-EN $935.00
    Impact Device DL for Hardness Tester dynaROCK II - Impact device with longer impact body. The diameter of the front pipe is 0.17" (4.2mm) HT-BAQ-21-121-EN $1,065.00
    Impact Device G for Hardness Tester dynaROCK II - Impact device with increased impact energy e.g. for measurements on heavy castings and forged parts. Measurement only in the Brinell range up to 650 HB. The requirements on the surface are not as exte HT-BAQ-21-125-EN $2,030.00
    Mobile printer for dynaROCK II HT-BAQ-21-112-EN $595.00
    Rebound Hardness Tester dynaROCK II with impact device D, test block, USB charger, direct data transfer to a USB flash device, test certificate, robust aluminum case HT-BAQ-21-100-EN $2,315.00
    Set of support rings for convex and concave surfaces, 12 pieces HT-BAQ-21-110-EN $345.00
    Test Block for Leeb Hardness Tester Ø3.5"x2.2" (Ø90x55mm), 6 lbs. (2.73kg); Engraved hardness scales: HLD, HLDL, HLD+15, HLC; Possible hardness values: 530±40HLD, 630±40HLD, 790±40HLD HT-BAQ-HVP-HLD-EN $295.00
    Test Block for Leeb Hardness Tester Ø4.7"x2.8" (Ø120x70mm), 13.6 lbs. (6.17kg); Possible hardness values: 500±40HLG, 590±40HLG HT-BAQ-HVP-HLG-EN $365.00
    Test Block for Leeb Hardness Tester with DKD/MPA-Certificate Ø3.5"x2.2" (Ø90x55mm), 6 lbs. (2.73kg); Engraved hardness scales: HLD, HLDL, HLD+15, HLC; Possible hardness values: 530±40HLD, 630±40HLD, 790±40HLD HT-BAQ-HVP-HLD-Z-EN $470.00
    Test Block for Leeb Hardness Tester with DKD/MPA-Certificate Ø4.7"x2.8" (Ø120x70mm), 13.6 lbs. (6,17kg); Possible hardness values: 500±40HLG, 590±40HLG HT-BAQ-HVP-HLG-Z-EN $545.00
    USB Charger for Hardness Tester dynaROCK II including cable HT-BAQ-21-130-EN $75.00